Start

content_cover

SkinFirmor RF

1.

What is the SkinFirmor RF?

4

2.

How does the SkinFirmor RF technology work?

4

3.

Range of applications

4

4.

Contraindications

5

5.

Radio frequency parameters

6

1. Intensity

6

2. Duration of use

6

6.

Safety of the application

6

7.

What should be considered before using SkinFirmor RF?

7

8..

How does the skin react to an application with SkinFirmor RF?

7

9.

What must be observed after using SkinFirmor RF?

7

10.

Spa treatments with the SkinFirmor RF

7

11.

Treatment technique

8

12.

RF treatment procedure

12

13.

Integration into BABOR treatment processes

13

What is the
SkinFirmor RF?

How does the SkinFirmor RF technology work?

Range of
applications

Contraindications

Radio frequency parameters

Safety of the application

What should be considered before using SkinFirmor RF?

How does the skin react to an application with SkinFirmor RF?

What must be observed after using SkinFirmor RF?

Spa treatments with the SkinFirmor RF

Treatment
technique

RF treatment
procedure

Integration into BABOR treatment processes

SkinFirmor RF

1. What is the SkinFirmor RF suitable for?

The BABOR TECH SkinFirmor RF is suitable for the professional local treatment of wrinkles around the eyes, mouth and forehead.

2. How does the SkinFirmor RF technology work?

The SkinFirmor RF works with a monopolar radio frequency of 4 MHz and is therefore ideal for local application on the face.

content_arrow

Radiofrequency has its origins in medicine and is considered a stimulant for cell renewal and collagen synthesis.

The energy of the radiofrequency is channeled into the depths of the skin with a special electrode, thereby reaching the dermis and causing the water molecules in the tissue to vibrate.

These vibrations heat the treated tissue to a maximum of 41°C in a controlled manner when used correctly. As is generally known from radiofrequency treatments, this mild heat development, which is perceived as pleasant, is sufficient to promote the skin's own regeneration mechanisms and the formation of new collagen and elastin.

In addition, microcirculation and lymphatic drainage are increased so that the tissue is optimally supplied with nutrients and oxygen and deposits/protein waste can be removed.

When used correctly, skin-damaging burns or denaturation of proteins are avoided.

At the same time, the moderate tissue heating causes collagen fibers in the connective tissue to contract, making the skin in the treated area appear firmer and smoother.

Professionally applied, SkinFirmor RF achieves visible results after just one application and gives the eye, mouth and forehead area a fresher, more youthful look.

3. range of applications

Treatment with the SkinFirmor RF in the area around the eyes, forehead and mouth is suitable for all skin types, especially for the following objectives:

content_arrow

- Optical reduction of lines and wrinkles

- Support for tissue strength

- Optical reduction of bags under the eyes and dark circles around the eyes

- Relaxation and refreshment for stressed, strained eyes caused by stress, screen work, fatigue, air conditioning, draughts, intense facial expressions

4. contraindications

As with any cosmetic treatment, only healthy people with healthy skin may be treated with SkinFirmor RF by appropriately trained beauticians.

In certain cases, use is contraindicated locally, generally or until normal health has been restored. The following list shows the most common contraindications.

If in doubt, you should always consult the specialist treating you.

Localized contraindications:

Skin areas with

- Skin damage (e.g. open wounds, localized inflammation)

- Visible skin changes (e.g. warts)

- Moles and birthmarks

must be generously avoided during use.

Treatment with SkinFirmor RF is generally contraindicated in the following cases:

- Blood clotting disorders

- Heart diseases

- Vascular diseases, e.g. thrombosis

- Severe circulatory disorders

- Diabetes

- Cancers, malignant tumors

- Diseases of the nervous system, such as Parkinson's disease, epilepsy, multiple sclerosis, facial paralysis

- Autoimmune diseases

- Rosacea

- Pacemaker

- Implanted insulin pump

- Metal implants in the area to be treated

- For use in the eye area: Glaucoma (glaucoma)

- Pregnancy or breastfeeding

- Under the influence of alcohol or drugs

In the following cases, treatment with SkinFirmor RF is contraindicated until normal health has been restored:

- Acute fever, infectious diseases

- Acute herpes in the area to be treated

- Acute conjunctivitis, other inflammations in the eye or mouth area

- Acute intake of antibiotics

The following cases are temporary contraindications:

For treatment of the eye:

- Cataract surgery (insertion of artificial lens): at least 8 weeks break

- Lasik (for the treatment of defective vision): at least 8 weeks break

- Glaucoma or retinal surgery: at least 3 months break

For treatment in general:

- after chemical peelings, peeling treatments

- After a fruit acid peeling treatment at the beautician: at least 2 weeks break

- after TCA peeling / phenol peeling: at least 6 - 8 weeks break

- after ablative laser treatments at the dermatologist: at least 6 - 8 weeks break

- after cosmetic surgery & injections in the last 6 months: Consultation with the specialist

In general, allergic reactions to the cosmetic products used may occur when using SkinFirmor RF.

5. Radio frequency parameters

1. Intensity

Regulates the intensity / strength with which the radio frequency is applied to the skin and can be set manually in the range 1 - 10.

Remember: the higher the intensity, the faster the tissue heats up!

Optimal settings:

Gentle

Medium

intensive

5

6

7

The sensation of the RF application and the skin reactions can vary greatly from person to person. For the ideal setting, obtain feedback from the client at the start of the treatment and each time you change the treatment area. The radiofrequency should always be felt with
a pleasant warming sensation; then the intensity is optimal.

Keep the handpiece in contact with your skin when adjusting the intensity up or down.

Consistently monitor the reddening of the skin during the entire application. If very intense reddening of the skin occurs, reduce
the intensity.

2. Application duration & speed of handpiece guidance

The duration and speed of application also have a considerable influence on the tissue heating achieved and therefore on the intensity of the treatment.

Note: The longer and the slower a certain area is treated, the more intensive and even the tissue heating!

6. Safety of the application

The success of treatment with the SkinFirmor RF depends not only on the selected intensity but also very much on the optimum application time and speed of handpiece guidance.

content_arrow

Preset programs with precisely illustrated step-by-step application sketches for each skin area ensure the optimum intensity and duration of the radiofrequency application. As a rule, skin areas of a maximum of 3 cm² are treated with fixed application times in order to achieve targeted and even tissue heating. All values were determined in extensive test applications

Eye area:

content_arrow

Program

Skin areas

Preset
intensity

Duration
in minutes

Total duration

Eyes above

Upper eyelid

Movable eyelid

5

5

2 x 3

2 x 2

10

Eyes down

Lower eyelid

Crow's feet

6

6

2 x 2

2 x 3

10

Total

Upper eyelid

Movable eyelid

Lower eyelid

Crow's feet

5

5

6

6

2 x 3

2 x 2

2 x 2

2 x 3

20

Mouth area:

content_arrow

Program

Skin areas

Preset
intensity

Duration
in minutes

Total duration

Nasolabial folds

6

2 x 3

6

Mouth

Upper lip wrinkles
(right / left)
Lower lip wrinkles

(right / left)

6

6

2 x 1,5

2 x 1,5

6

Total

Nasolabial folds

Upper lip wrinkles

(right / left)

Lower lip wrinkles

(right / left)

6

6

6

2 x 3

2 x 1,5

2 x 1,5

12

Special:

content_arrow

Program

Procedure

Preset
intensity

Duration
in minutes

Total duration

Forehead wrinkles

3 cm length each: 3 min.

5

3 x 3

9

Glabella
(frown line)

6

3

3

Marionette folds

6

2 x 3

6

Once the application time for a specific skin area has been reached, a short signal tone is emitted. At the same time, the next treatment area is automatically shown on the display and the application time for this area starts again. This makes it easier to use the device precisely and safely. Once the selected program has finished, the application ends automatically.

Note: Please note that the intensity is automatically reset to the preset value each time the skin area is changed. If necessary, the intensity per skin area must be readjusted again and again to determine the individual ideal value. Bear in mind that the sensation can vary greatly even from the right to the left side of the face.

7. What must be observed before using SkinFirmor RF?

Contact lenses should be removed before radiofrequency applications. As there may be interference with hearing aids, please also have your hearing aids switched off.

8. How does the skin react to an application with the SkinFirmor RF?

The skin reacts to the treatment with slight to intense redness, possibly also with a slight burning sensation, tingling and feelings of tightness. Swelling may also occur in rare cases. These reactions usually disappear after 1-2 days.

Visible vessels may initially appear intensified after the treatment; however, this usually disappears after 1-2 hours.

9. What must be observed after using SkinFirmor RF?

Optimum treatment success is achieved if the client avoids the following on the day of treatment and on the following days until the redness/reactions have completely subsided:

- Heavy sweating (sauna visits)

- Solar radiation / Solarium

- Hair removal in the treated areas

- Swimming pool visits (chlorinated water / seawater)

Once the redness/reactions have subsided, all activities can be resumed as usual.

During a treatment course with SkinFirmor RF, we recommend using sun protection with a very high sun protection factor from the DOCTOR BABOR SOLAR DEFENSE range throughout the day. The best way to protect your eyes is to wear sunglasses with UV protection.

Even after the end of the treatment, sun protection should be worn during the day for a further 2 - 3 weeks.

10. spa treatments with the SkinFirmor RF

To achieve maximum treatment results, we recommend a course of 6 treatments over 3 weeks, accompanied by consistent home care

11. treatment technique

Position the client's head for the treatment of each facial area so that you can work optimally.

Always move the handpiece very slowly and without pressure over the skin - in a straight line or in very small circles, depending on the instructions.

Make sure to maintain constant skin contact and to put the handpiece down as little as possible.

content_arrow

Always treat the right eye/mouth area first, then the left, as shown in the application sketches on the display after selecting the program.

If possible, work on the right side with the right hand and the left side with the left hand.

To ensure that the RF application is as pleasant and relaxing as possible, please note the course of the blue and red lines / circles on each application sketch; as a rule, blue lines indicate the "outward path" of the handpiece into an RF-sensitive application zone, red circles - executed very slowly - indicate the handpiece guidance for targeted tissue warming.

What must be observed before fitting the handpiece?

1. Put on disposable gloves.

2. Place the return electrode under the client's upper back on the couch away from the heart.

3. Select the program.

4. Remove the Radio Frequency Glycerin Gel from the jar using a spatula and apply it evenly to the areas of skin to be treated using a narrow brush (e.g. eyeshadow brush).

5. Start the program. Initially maintain the preset intensity until the customer reports a pleasantly noticeable warmth. You can then readjust the intensity if necessary (-/+).

Eye area

Programs

- Eyes above

- Eyes down

- Total

First treat the right eye, then the left eye.

Top eye

content_arrow

1. Skin area: below the eyebrow up to the eyelid crease

1. Start on the outside below the eyebrow and slowly move inwards in a line.

2. Perform slow circles from the inside to the outside.

3. Repeat 1. and 2. until the time is up.

Note: Glide to the next starting point with skin contact.

content_arrow

2. Skin area: mobile eyelid

1. Start at the level of the temple and slowly move inwards in a line over the movable eyelid.

2. Perform slow circles from the inside to the outside.
Attention: always keep a distance of 0.5 cm from the edge of the eyelid!

3. Repeat 1. and 2. until the time is up..

Eye below

content_arrow

1. Skin area: lower eyelid area

1. Start at the level of the temple and slowly move inwards in a line along the lower eyelid.

2. Perform slow circles from the inside to the outside.

3. Repeat 1. and 2. until the time is up.

Note: Glide to the next starting point with skin contact.

content_arrow

2. Skin area: Crow's feet

1. Perform slow circles.

Treat the left eye in the same way.

Mouth area

Programs

- Nasolabial folds

- Mouth

- Total

First treat the right, then the left nasolabial fold / mouth area.

content_arrow

Nasolabial folds

1. Start at the corner of the mouth and move slowly in a
line until just before the wing of the nose. (Do not touch
the nostrils!)

2. Work out the nasolabial fold with slow circles from top to bottom

3. Repeat 1. and 2. until the time is up.

Note: If the mouth area is also being treated, switch to the other side via the upper lip area to treat the left nasolabial fold.

Mouth

content_arrow

1. Skin area: Upper lip wrinkle area

1. Start at the corner of the mouth and slowly move in a line to the middle of the upper lip.

2. Slowly circle from the center outwards.

3. Repeat 1. and 2. until the time is up.

Note: Switch to the other side via the upper lip area to treat
the left side of the upper lip.

content_arrow

2. Skin area: area of the lower lip wrinkles

1. Start at the corner of the mouth and slowly move in a line to the middle of the lower lip.

2. Slowly circle from the center outwards.

3. Repeat 1. and 2. until the time has elapsed.

Note: Switch to the other side via the lower lip area to treat the left side of the lower lip.

Special

Programs

- Forehead wrinkles

- Glabella (frown line)

- Marionette pleats

3 cm wrinkle length are treated for 3 minutes each.

content_arrow

Forehead wrinkles

Work the folds back and forth in slow circles in 3 cm sections.

= 3 Minuten

content_arrow

Glabella (frown line)

Work the fold back and forth in slow circles.

content_arrow

Marionette pleats

Work the folds back and forth in slow circles.

First right, then left

12. Treatment procedure

The RF application with the SkinFirmor RF can be integrated into many other BABOR treatments at the appropriate point. The aftercare consisting of LIFTING Derma Filler Serum and EXPERT SPECIALISTS Eye & Lip Sheet Mask or EXPERT SPECIALISTS Smoothing Sheet Mask should always be adhered to and a facial massage should be avoided.

1.

Medical history/consultation interview and skin analysis with the Derma Visualizer.

2.

Information & clarification on SkinFirmor RF application.

Ask for contraindications and have them signed.

3.

Preparation

Prepare warm (38 - 42°C) and cool (14 - 18°C) compress water.

4.

Query

Contact lenses? → Have them removed

Hearing aids? → Have the RF application switched off before starting

5.

Grounding Ritual

6.

Deep Cleansing Ritual (cleansing)

Selection of cleanser and toner to suit the skin's appearance/condition

Remove cleansing with hydro-therapy stimulation.

7.

Vitality Analysis & Boost

(skin activation & vitality check)

Skin Activator Gel (circulation mask)

Lose weight immediately with hydrotherapy stimulation.

8.

Manual and visual skin diagnosis

9.

Peeling

Compress technique Selection of peeling and toner to suit the skin's appearance/condition

Remove peeling with hydro-therapy stimulation.

10.

RF application

1. Put on disposable gloves.

2. Place the return electrode under the client's upper back (away from the heart) on the couch. Ensure complete skin contact!

3. Have the customer close their eyes/mouth.

4. Remove the glycerine gel with a spatula and apply evenly to all areas of the face to be treated using a narrow brush (e.g. eyeshadow brush).

5. Select and start the program.

6. Check intensity.

7. If necessary, readjust the intensity while remaining in contact with the skin.

8. Perform RF according to 11. treatment technique.

9. The program ends automatically after the fixed application time has expired.

10. Remove the counter electrode.

11. Remove excess glycerine gel after application with a damp sponge.

11.

RF aftercare 1

Apply LIFTING Derma Filler Serum generously to all treated skin areas and work in. Once the serum has been absorbed into the skin, apply an additional layer and work in.

12.

Lymphatic
Activation & Active Infusion

(active ingredient concentrate)

Ampoule Concentrate or Serum according to skin appearance/condition and treatment goal.

13.

Face Sculpting Massage

Massage cream according to skin type/condition and treatment objective.

14.

RF aftercare 2

Apply EXPERT SPECIALISTS Eye & Lip Sheet Mask to the skin areas treated with RF and smooth out.

Treat the remaining skin with a cream mask suitable for the treatment objective.

Application time: at least 8 minutes

Remove excess with hydrotherapy stimulation.

Alternative

EXPERT SPECIALISTS Smooting Sheet Mask

Application time: at least 8 minutes

Work in any excess after the application time.

15.

Final care

Eye care and cream according to skin type/condition and treatment goal.

16.

Reawakening Ritual

17.

Cleaning the appliance

Clean & disinfect the SkinFirmor RF according to the technical operating instructions.

13. integration into BABOR treatment processes

The following overview shows how you can combine the SkinFirmor RF application with other BABOR treatments and applications.

For all BABOR TECH combinations, please observe the special features of the respective technology and its regulations for safe use.

* Execute PolishFusion after MDA

** Perform 10 % AHA according to MDA

*** Apply Peeling Liquid & Mask beforehand; aftercare with serum suitable for MDA